What’s new in Axomek 0.1.12
Released
Changes in detail
Results that change when a saved project is solved again:
- Bearing fits take steel rings (and a steel shaft or housing chosen from the app's material list) at E = 210 000 MPa instead of 208 000 MPa, as through- hardened bearing steel is usually given and the reference solver took it: fit pressures rise by about 1 % and the clearance lost to the fits changes slightly. The ratings keep the 207 000 MPa of ISO 76 and ISO 281.
axm set,sweepandoptimize --varyread some fields in their proper unit:viscosity40in mm²/s (it was read as °C), friction coefficients, cycle counts and similar dimensionless fields without a unit (they had N·mm or h),ratingDistancein km, spring densities in kg/dm³ and bolt temperature rises in K. Values given with an explicit unit, and JSON, were always read correctly.