Changes in detail
The Overview's Power loss, the results panel's total and the project preview mark a total that leaves a stage's loss out as partial, naming the stages (user test RR1 planetary, U-A17: a 3 kW three-stage gearhead at η 0.97 a stage read "Power loss 2.64 W", one planet bearing's friction, beside about 260 W in its stages; now "partial: without PG1, PG2, PG3"). Such a total is no value for the design search, a constraint or a comparison (the
powerLossmetric is not available, as a check not determined is), so no design passes a power-loss limit on the stages it does not count. The report's list of stages left out now says what each is (a refused drive read "gear pair: not solved").A plan that withholds Drives no longer keeps their power and efficiency beside a total of the bearings alone (audit TA-F26: the Belt drive example's 19.3 W total showed efficiency 94.7 % and 95 %, the drive's). A withheld stage's power, efficiency and loss are left out together:
transmittedand both efficiencies are absent and the stage is named among those the total leaves out (notComputed), as for gears, rack meshes and the ball nut, now for every withheld module with losses.The power flow has the steering's ball nut as a stage, from its shaft to the rack while the motor steers (back while the rack drives the nut), with what passes its thread, its thrust at the rack's speed and its efficiency in the state, as the power loss counts it (audit TA-F50: the Ball-nut EPS example's rack read as taking the pinion's 276.5 N, its own network apart from the nut's; now one network, the rack taking 6 041 N, 276.5 N from the pinion and 5 764 N from the nut, 362.4 W of the 411 W put in, 88.19 % with the bearings). Each stage, train and path at standstill has its ratio from its geometry (tooth counts, pulleys, lead), not ∞ (audit TA-F44: the Gear pair example at 0 rpm, ratio ∞ → 3).
Housing imports (RR1 audits S-07, S-11, O-06, O-11, O-12): a Matrix Market file is held to its size line, square, every entry inside it and exactly the entries (or values) it calls for, and a Harwell–Boeing file to its header's counts, column pointers and rows. A file cut off between two entries was read with the missing ones as 0, a stiffer housing: a symmetric 2 × 2 seat matrix, diagonals 100 000 N/mm and a coupling of −90 000 N/mm, under the first support of the simple template gave a deflection of 0.2017 mm against a limit of 0.23 mm, a pass, where the whole file gives 0.2584 mm, a fail. It is now refused as incomplete ("its size line (line 2) calls for 3 entries, but only 2 follow"), saying to export it again. A file cut inside its last entry keeps the count but reads its value with digits lost (−100 000 as −1000): a Matrix Market file that stops in its last line without ending it, and a Harwell–Boeing line that ends inside a field, are refused as incomplete too, so a whole Matrix Market file written without a line break after its last entry is refused as well (add the line break, or export it again; every FE program's export ends it). A Harwell–Boeing format with a field width of 0 is refused with its line, where it stopped the engine. A reduced matrix of more than 600 degrees of freedom, a full model's rather than one reduced to the seats, is refused before it is assembled, naming the count and saying to reduce it to the seat nodes: 64 000 dofs, 1.6 MB of text, took 16 GB before, and 12 000 dofs ran for minutes. A saved project whose matrix has more is refused when solved, with the same message; every template and test matrix is far below (the largest has 12). A Nastran mesh's MAT1 E outside 500 to 500 000 MPa in the model's units (steel in GPa or in Pa) is refused as RHO is, naming the MAT1 and the unit to give, where it made the housing rigid or rubbery without a word. Files that read before and keep to their headers read as before.
An eccentric bolted joint whose interface is larger than VDI 2230's limiting size G in the bending plane (R0, Eq. 54, 55: G = dW + hmin for a through bolt, 2·dW for a tapped thread) has the checks that rest on the eccentric model not determined: the preload, the residual clamp load after yielding, the yield, fatigue, surface pressure and slip safeties pass no more (a warning saying why and what to do); a fail stays a fail, marked approximate (an opening fail too: beyond G the real pressure gathers near the bolt, so an edge the linear model finds open opens). Shearing and the thread engagement do not change. Before, they passed plainly, with a note only in the report (RR1 user test, from feedback). The tester's hoist bracket, M16 8.8 through 20 + 15 mm plates with cT = 130 mm against G = 37.5 mm (ssym 35, a 15, u 65 mm): fatigue 58.82, slip 8.272, yield 1.174, surface pressure 1.474 and the preload pass → not determined (the values stay). A joint within G, and VDI 2230's examples B4 (G = 32.3 mm, cT = 12 mm) and B5 (G = 57.7 mm, cT = 33 mm), do not change.
interfaceLimit(cT, G, whether exceeded) is new in a bolt's results.A bolt's opening check where the preload alone lifts the far edge V says why in its message: the interface pressure at V with its sign (Eq. 99 counts compression as negative, so above 0 is a tension), which the bolt panel's row shows against 0 MPa, the condition IBT/AD + ssym·xV ≤ 0 as its formula, and Show the calculation (the opening check had none). Before, it read "44 119 N, limit 0, FAIL", beside a pressure of 2.195 MPa with no sign (RR1 user test, from feedback). The check's value and limit stay the clamp load FK against FKab in N, as in 0.2.7 and in every other case, so
--json, comparisons and the report give one quantity and unit for the check (the hoist bracket: 44 119 N / 0 N with +2.195 MPa at V, still a fail, approximate beyond G). Its utilisation there is unbounded ("inf": no clamp load closes V), so a comparison never ranks such a joint ahead of one failing by a finite share;axomek variant compare --jsonwrites it as "inf", asaxomek solvedoes. The verdict does not change. Show the calculation of a closed interface writes out FKab (Eq. 107) and FK (Eq. 102): VDI 2230's B5 gives FKab 68 130 N, as printed.A torque-tightened bolt's yield check says when the tightening sets it: where what the joint carries raises its working stress σred,B by 10 % or less over its value at FM,zul alone, the check's message says so, and its fix hint no longer advises a larger thread or a higher property class (each is tightened to the same ν of its yield point). Before, the hoist bracket's 2.4 kN on an 81 kN preload read "close to its limit" (1.174) with "a larger thread or a higher property class" (RR1 user test, from feedback). The numbers do not change; the Bolted bracket template's yield check (1.169, its load adds 1.3 % to the bolt's preload) says it too.
The report and the parts list print what the model rates (RR1 audit; the results do not change). A chain's or toothed belt's sprockets and pulleys are their pitch diameters from the pitch and teeth, with the teeth, not the diameter fields kept from a belt: ½ in chain, 19/38 teeth, Ø125/250 → Ø77.16/153.8 mm in the report (77.159/153.791 in the parts list). A gear with a face width of its own (
details.faceWidths) is listed at it (pinion b 30 → 40 mm with widths 40/30 on a pair of b 30), and the report's gear section names both widths beside the pair's. A support on a housing stiffer one way shows each plane's stiffness, xy and xz, where it showed the xy plane's alone (Housing seats example: B1 and B2 3 550 909 → 3 550 909 (xy) / 896 645 (xz) N/mm); a coupled bearing's also names its housing's. The report says which parts are left out by name ("Bearing BR2"), not by key ("bearings.BR2"). The bearing catalogue import reads quoted cells as RFC 4180 writes them:"Part 07, batch A"was imported asPart 07; a row with text past the header's named columns, a quote left open or text after a closing quote is now refused with its line, counted in the file as it is (blank lines too). A project of one chain drive gives its ratio in the summary as z2/z1, as the solve does (19/38 teeth: 1.993 → 2).