Sign in

What’s new in Axomek 0.3.1

Released

In short

Axomek 0.3.1 is a smaller release: a gear pair's oil temperature for its efficiency, a roller crowning search that finds an optimum where it used to give up, Make it pass that tries every tighter fit class, safer housing imports, bearing clearances typed in µm and more of the app by keyboard. Few results change when a saved project is solved again: each section below says which, by about how much, and what to check again. The full list of changes for developers follows.

Gear pairs

New: Oil temperature (mesh loss), beside the oil viscosity. The mesh loss takes the oil's viscosity at that temperature, from its viscosity at 40 °C and a mineral oil's viscosity index of 95, as a bearing's oil grade does.

  • A pair without one, every pair saved before, takes the oil at 40 °C as before, so saved projects keep their results.
  • In a hot sump that is optimistic: at 95 °C an ISO VG 220 oil's mesh loss came out about 11 % low, so the efficiency slightly high and the heat slightly low. Give the oil's working temperature for gearboxes that run hot.
  • In a gear train the efficiency carries the torque from stage to stage, so once a temperature is given the torques the train passes on, and the safeties of pairs that take their torque from it, move slightly too.
  • The scuffing check keeps its own oil temperature, as before.

Bearings

  • The roller crowning search (Roller profile in a bearing's detailed results) now finds an optimum near the limit of what a tapered roller bearing can carry, where it used to time out with none: a single 30207 under 4000 N radial and 1000 N axial now has one (1955 MPa against 2101 MPa as entered), in under a second instead of some 25 s.
  • Where the search cannot go on, the card says why ("not determined", with a hint such as a little more axial load or the bearings as a pair) instead of offering the best of the few crownings that solved: the same bearing free to tilt under 1200 N axial offered straight rollers at 6114 MPa and now has no optimum.
  • Every example and a sweep of tapered, cylindrical and spherical roller bearings give the same crowning as before. Re-check only roller profiles of bearings loaded close to their axial limit.

Keys, splines and fits

  • Make it pass on a press fit that slips tries every tighter shaft class up to s6, not only the next three: a k6 shrink fit that only s6 holds now gets s6.
  • A class that grips but fails the hub's or the shaft's yield check, or whose yield check is not determined, is no longer proposed; the next class with the same grip and less interference is tried. Where none holds, the proposal says which class failed which check.
  • Each proposal names the shrink temperature it needs (not checked). A fit that slips even at s5, s6 or s7 is told that no class grips more.

Housings

  • An FE import (a Nastran mesh or a stiffness matrix) always makes a new housing; it no longer replaces one. To change a housing's model, import the new one, relink the seats and the press fits to it, then remove the old housing.
  • A mesh or matrix file's units are always asked, never guessed: the app asks Millimetres or Metres and shows the model's size either way. Before, a mesh under 5 units across was taken in metres and a matrix in mm. Scripts give the unit with the import.
  • A seat that a bearing support, a press fit or a rib sits in can't be moved or replaced by an edit: unlink or relink first. Resizing a linked bore is still allowed.
  • A support or press fit in a seat its housing doesn't have was rated in the housing's last seat. Such a project is now refused as a whole: it reads "Refused" with the seat named, in the app, the report and the command line, never a pass. Pick a seat or unlink it. A valid project's results don't change.

Keyboard and opening files

  • Every control that reacts to a click can be reached and used from the keyboard, and a check in the build keeps it so.
  • Find a bearing, Design search and Make it pass close on Escape also after the button that had the focus went away (Search turning into Cancel), and Escape stops a running search.
  • On the web, when the browser shows no open dialog, the note offers Choose a file…, which takes the focus, so a file opens without dragging it. A file that cannot be read says so; nothing opens and the project stays as it was.

Units

No result changes, but one field reads differently:

  • A bearing's radial and axial clearance, and a shaft pair's axial clearance, are shown in µm (mil with US units), as the results, the report and the command line already showed them, no longer in mm. A bare number typed there is now in µm: type 20 for 20 µm. A number typed with its unit reads as before (0.02 mm is still 20 µm).
  • A torque typed into a clearance or another µm field (20 N·m) is refused; the command line read it as 20 nm.
  • The app and the command line now read the same units, with the same factors, and show the same US customary units; what they still read differently on purpose is listed in the README's known limits.

Privacy and usability replays

  • The app asks its privacy question once more: Feature statistics and Usability replays both stay off until you answer, and each is kept as its own choice, changed in Settings › Privacy & data.
  • Usability replays are back in the web app, only if you allow them. Every text and number you type or see, drawings and private screens are blanked out; a replay can still show when you made changes, which options are selected, whether a result passed or failed, and the window size. The desktop app never makes replays.
  • Statistics and replays go only as the account, and under the choice, they were collected for.
  • Reload browser tabs left open from 0.3.0 after updating: changes made in them don't reach the new version.

Changes in detail

Results that change when a saved project is solved again:

  • The privacy choices are kept per switch (see Usage analytics, session recordings and feedback), and every statistics batch and replay goes only as the account, and under the choice, it was collected for. Usability replays are on again in the web app, with what a replay can still show said in the privacy texts (when changes were made, which options are selected, whether a result passed or failed, the window size). The privacy choice is asked again once (consent texts version 4, consentVersion in events.ts and the account service's CONSENT_VERSION): a choice made under version 3 does not hold, and both stay off until the user answers again.

  • No result changes. The app shows a bearing's radial and axial clearance, a shaft pair's axial clearance and the pair's clearance changes in µm (mil with US units), as its results, the report and axomek already did, no longer in mm (in): a bare number typed in such a field is now in µm. A number typed with its unit reads as before, and 0.02 mm is still 20 µm. A design search shows a radial clearance it varies in µm too, and the settings' default support tilt limit says arcmin, not ′ (R-931). A torque typed into a µm field or a clearance (20 N·m, 20 Nm) is refused, in the app and in axomek, where it was read as 20 nm: only nm written so is nanometres there.

  • Make it pass on a fit that slips tries every tighter shaft class the app offers, up to s6 (from k6: m6, m5, n6, n5, p6, r6, s6), not only the next three, so a k6 shrink fit that only s6 holds now gets s6 (R-160). A class that clears the slip check but fails the fit's hub or shaft yield check was proposed with that yield among the checks it breaks; it is no longer proposed, nor is one whose yield is not determined (the steel's yield strength only estimated at the part's size): the next class with the same grip and less interference (n5 after n6) is tried, and where none holds, what was tried names the class and the check. Each proposal names the shrink temperature it needs (not checked). A fit that slips at s5 or s7 is advised, as at s6, that no class grips more.

  • The roller crowning search of a bearing's detailed results (Roller profile) tries a crowning that does not balance from the last one's solution from the geometric guess as well, before larger loads. A single 30207 under Fr 4000 N and Fa 1000 N, just above the Fr·tan α it needs, took some 25 s for its detailed solve and showed no Roller profile; it now has one (k 1.1·10⁻⁴, 1 955 MPa against 2 101 MPa as entered), in under a second. Once larger loads have failed to balance a crowning with rollers carrying, the next such crowning stops the search, and the card says why instead of offering the best of the crownings that solved: the same 30207 free to tilt under Fa 1200 N offered straight rollers at 6 114 MPa, from a few crownings, and now has no optimum. Every example and a sweep of loads, clearances and tilt on tapered, cylindrical and spherical roller bearings give the same crowning as before otherwise. solve --json gains profileNote (additive).

  • Housings (R-020, R-021, R-022): a support or press fit in a seat its housing doesn't have (a seat number above its count, or a link with no seat to a housing without seats) was rated in the housing's last seat; it now refuses the whole project ("support B1 of SH2 is in seat 2, which housing H1 doesn't have": pick a seat or unlink it), and the app, the report and every axomek reader say "Refused", never a pass (check exits 1, solve, summary, report and tree exit 3). A valid saved project's results don't change. An FE import always makes a new housing: importHousingMesh and importHousingMatrix (and axomek housing import --id) with an existing housing's id are refused; import as a new housing, then relink the seats. A Nastran mesh or a matrix without its length unit is refused instead of guessed (a mesh was taken in metres when it was under 5 units across, a matrix in mm): give --length-unit (lengthUnit); the app asks Millimetres or Metres with the mesh's size. An edit that moves or replaces a seat a support, fit or rib sits in is refused: unlink or relink first.