Racks
Translating bars, toothing flats, yokes, bushings, tie-rod ends and their state results.
- DIN 743
A rack is a translating bar in the shaft module: sections with an optional toothing flat, bushings, a yoke opposite the pinion, tie-rod ends and a state at a chosen displacement. It slides along its local +x axis and carries no torque. It is solved as a beam with a piecewise yoke law and rated by DIN 743 with fully reversed stresses and for Euler buckling per free span; key checks are the yoke's regime (seated, lifted, on the stop), strength at the flat and buckling. Open Steering rack or choose Rack under the title in the shaft module (an undoable switch; a conversion that leaves incompatible supports or loads is refused with a hint at the field to change), and read Member and toothing flat first: fatigue at the flat needs your own notch factor.
Member and toothing flat
Sections, loads and tie-rod ends belong to the moving bar. Supports and mounted mesh seats belong to the housing. At displacement s, a housing position x acts at x − s on the bar. Results show the selected state.
For a section, turn on Flat under Toothing flat. Its starting depth is 0.2 times the diameter, rounded to 0.1 mm. Depth must be positive and less than half the difference between outer and bore diameters. Faces is the outward normal about +x, measured from +y: 0°, 90°, 180° or 270°. The removed circular segment changes area, centroid, second moments and the stress at the root plane. The shaft's STEP and DXF exports and its drawing refuse a member with a flat, which they would give out round.
Notch factor βσ must be at least 1. Give a value from tests or FE for your toothing. Without it, fatigue at the flat is not computed, with a hint; the beam and its nominal stresses still solve. DIN 743 supplies no notch factor for a toothed rack bar. The template's R2 value 2.0 is an assumed notch factor: replace it with your own. FKM is unavailable for a rack.
Yokes and bushings
A Yoke sits opposite the pinion, at the mesh direction plus 180°. Enter plug preload F0 in N (at least zero), spring rate in N/mm (positive), clearance to the stop in mm (at least zero), stop stiffness in N/mm (positive), and friction coefficient μ (at least zero). The mesh's Yoke selector names this support, which stands at the mesh's contact: a yoke apart from its contact is refused (its plug's spring and the pinion would both hold the bar there). A yoke without a named mesh uses its section flat's direction, or 0°, and carries a warning to link it.
A Bushing restrains the bar radially and lets it slide and tilt. Radial stiffness is positive in N/mm, or empty for rigid. Its Friction μ is at least zero. + Support on a rack adds a bushing. Rack supports are axially floating and cannot link a rolling bearing.
Typical yoke clearances are 50–100 µm (Lenkungshandbuch, 2nd ed., p. 223). Rack forces of 7–15 kN and diameters of 24–32 mm vary with vehicle class (p. 266, Table K-5). A rack push-through force of 150–350 N is reported at 5–10 mm/s (p. 243); compare the computed friction with measurements under matching conditions. The starting values and these ranges are design inputs, not standard requirements or a design's limits.
State and tie-rod ends
In the Rack tab, Displacement s is finite in mm. Optional Travel from / to gives ordered limits containing zero, with s inside them; clear either field for no travel limit. All supports and mesh seats must stay on the bar at the selected displacement and the travel endpoints. Seals and bellows adds non-negative friction in N.
Each Tie-rod end has a position on the bar in mm, a non-negative share, and XY and XZ angles strictly between −45° and +45°. Shares are weights normalised by their sum, which must be positive when ends are present: 1 and 1 split equally, 1 and 3 split 25 % / 75 %. + End adds an end at the bar length with share 1 and angles 0. Each end balances its normalised share of net axial rack force, including axial gravity, and takes the transverse forces from its tie-rod angles. Editing one share is a single undoable command. Remove an end with its row's button.
Mounted meshes
In Rack and pinion, open Mounting and choose Mount on shafts. This uses the first rotating shaft and the first rack, both at position 0; edit the seats to match the design. A mesh mounted on a rack with tie-rod ends (or on the steering system's rack) is the steering gear's, edited in the Steering module (see A steering's racks are in Steering). Pinion shaft selects a rotating member, Rack a rack member. Both positions are in mm. Direction is measured about the rack's +x from +y towards the pinion; with a yoke or flat it must be 0°, 90°, 180° or 270°.
Driver selects Pinion or Rack. Pinion turns selects positive or negative rotation about local +x. Torque from: Given uses the mesh torque or rack force; Train resolves it from connected loads. A connected shaft speed overrides the mesh's standalone speed. Remove mounting returns it to standalone rating. Mounted rating uses the rack displacement, so the standalone Position field is disabled. A named yoke decides the lift and disables Lift: none while it is seated, else the bar's deflection at the contact away from the pinion. Without a named yoke, the stored Lift stays active and editable, and the bar's deflection at the contact adds to it.
Results and misuse
The Rack section follows Bearings. A yoke is seated, lifted or on the stop. It shows reaction, plug force, sliding friction, lift, and its mesh's contact ratios and backlash at that lift. Seated has a pass dot; lifted and on the stop have an amber dot, on the stop with a line saying what its stop carries (information: nothing fails there). Bushing rows show force and friction. Rack friction sums yokes, bushings, seals and bellows.
Entering a mesh Peak rack force adds forward and reverse Misuse states at that force. Each reports yoke regimes and the largest stress. Buckling lists the free spans between restraints and ball joints, compressive force, allowed force and safety. Exceeding the allowed force has a fail tone.
A mesh without a peak keeps its state loads in both misuse states. Reversing the rack force reverses the cross force and pitch-line moment; the separating force still pushes the members apart. Buckling includes the worst solved load case. A refused case leaves the duty buckling and strength checks uncomputed.
What a rack may carry
A rack member's state takes its sections (flats included), its yokes and bushings (each on a housing seat of its own; a yoke without a housing), its tie-rod ends, the rack meshes on it, and loads of forces, moments, a mass and a length. Anything else mounted on a rack is refused as not supported on a rack member, and the rack then has no state, so neither its meshes nor their pinions are rated: a rotor, a gear pair, a worm pair, a belt or chain drive, a coupling, a bearing, and a load's torque, balancing torque or unbalance. Put what such an item does on the rack as a load, or turn the pinion instead.
Method notes and limits
The beam uses the flat section's centroid and principal second moments, including the moment of the mesh force about the root-plane pitch line. Yoke equilibrium is solved with a piecewise spring law: seated against the pinion, lifting against the spring, then spring plus stop stiffness beyond clearance. Each mounted mesh is rated again at the rack's lift at its contact. DIN 743 fatigue takes each point's stresses in the state as fully reversed amplitudes, for steering left and right, the steady part of the separating force included: conservative for the usual mean stress sensitivity. Free-length buckling uses Euler load and the model's end-restraint factors; review its reported span and state. Ball joints, seated yokes (at their pinion contact) and rigid bushings hold the bar laterally; a bushing on a spring, and a yoke lifted off its seat (its spring, on its stop its spring and stop), holds it only when stiff enough, a bushing in its softer plane, to brace the compression beside it (k ≥ 4·P/L, P the larger compression and L the shorter span next to it), else its spans join over it, in each state and load case on its own. A strength peak factor above 1 is a state of its own, the static peak: the rack solved again at the factor times its loads, meshes and weight (a steering state's rack friction included, reported as that friction times the factor), so its yokes and sprung bushings act as they do at the peak. Its static strength and buckling checks read that state; a peak that cannot be solved (the bar lifted off its pinion, say) leaves the rack, its meshes and the pinions they drive unrated. Compression no span covers is reported as a warning, and its buckling is not computed. A yoke that comes against its stop, in any state the rack is rated in (the state, the static peak, the misuse states and each load case's), is listed with the force its stop carries: not a warning, since at a high separating force the plug normally comes against its adjusting screw, and the rack and the mesh are rated with the stop. The stop itself (the plug, its adjusting screw and the housing) is not checked: its force is listed under Not checked, and the verdict is no plain pass until you check those parts for it by hand.
Friction is a force estimate from support reaction and entered coefficients plus seal force. It does not model speed-dependent friction, stick-slip, lubrication or thermal losses, and is not deducted from the train's power balance. Tie-rod ends are point-force boundaries, not an elastic tie-rod model. No torsional, rotor-dynamic or FKM rack assessment is supplied. Travel endpoints check geometry; a duty spectrum and tooth-by-tooth stroke counting are not computed here. Verify the manufactured tooth geometry and application-specific fatigue inputs separately.